Annie Chemie P Ltd. India Annie Chemie P Ltd, is a company at Dahej in Gujarat, India. It is a manufacturer exporter of Potassium Chloride & Potassium Iodide and oil field shale gas fracking or hydraulic fracturing chemicals and speciality chemicals and it has substantial exports to countries like USA, Canada, UK, Europe, UAE, Nigeria, Algeria, Turkey, Mexico, Brazil, Chile, Argentina, Australia, Kuwait, Dubai etc. We have developed encapsulated guar gel breaker based on coated ammonium persulfate, potassium persulfate, sodium persulfate, potassium peroxymonopersulfate, sodium bromate etc. We also supply other coated or encapsulated products like citric acid, guar crosslinkers other shale gas frac related products like diverting agent, KCl-substitute or clay-stabilizer, corossion inhibitors, scale inhibitor, bio-guard and several speciality chemicals.

Home ----------------- Contact Us

Potassium Chloride SDS of Suppliers Exporters, Manufacturers

Potassium Chloride
CAS Number: 7447-40-7 USP BP Ph Eur IP Reagent FCC Food Grade Suppliers Exporters, Manufacturers
Potassium Chloride Manufacturers Exporters

Please visit Main Page of Potassium Chloride USP BP Ph Eur IP Reagent FCC Food Grade Manufacturers.

Potassium Chloride SDS, Safety Data Sheet
MSDS Sheet
12-May-22

1. Product Identification

Product Name & Other Names: Potassium chloride or Potassium monochloridehloride or MOP or Muriate of potash.
CAS No.: 7447-40-7
EINECS EC Number: 231-211-8
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.

2. Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Hazard Class and Category Code(s), Regulation (EC) No 1272/2008 (CLP)

Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.

Labeling according to Regulation (EC) No 1272/2008

GHS Label Elements
NONE

Signal Word: None

Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352 - IF ON SKIN: Wash with plenty of soap and water.
P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.

3. Composition/Information on Ingredients

Product Name & Other Names: Potassium chloride or Potassium monochloridehloride or MOP or Muriate of potash.
CAS No.: 7447-40-7
EINECS EC Number: 231-211-8

4. First Aid Measures

Always seek medical attention after first aid measures are provided.

Inhalation: If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: Induce vomiting immediately as directed by medical personnel. Never give anything by mouth to an unconscious person. Call a physician.
Skin Contact: Wash with soap and water. Cover the irritated skin with an emollient. Get medical attention if irritation develops. Cold water may be used.
Eye Contact: Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention.

5. Fire Fighting Measures

Fire: It is not considered to be a fire hazard.
Explosion: It is not considered to be an explosion hazard.
Fire Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide. Use means suitable for extinguishing surrounding fire.
Extinguishing Media Not recommended: None specified.
Extinguishing Media Not recommended: Avoid using solid water jet as it may scatter the fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At elevated temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used.

6. Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Do not approach facing the wind.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment cleanup procedures and Storage: Contain spilled material. Do not let the product enter drains. Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow evacuating as per law.

7. Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.).
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Do not store with incompatible materials like strong oxidizing agents, bromine trifluoride, potassium permanganate plus sulfuric acid. Hygroscopic.

8. Exposure Controls/Personal Protection

Airborne Exposure Limits: None established.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator (NIOSH type N95 or better filters) may be worn.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full-face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Handle in accordance with good industrial hygiene and safety practice.

9. Physical and Chemical Properties

Appearance: White crystals or powder.
Odor: It is odorless.
Odor threshold: Not applicable.
pH: No data found.
Relative density: around 1.99
Boiling Point: 1500C (2732F) Sublimes.
Melting Point: 772C (1422F).
Flash point: Not available.
Auto-ignition temperature: No data found.
Decomposition temperature: No data found.
Upper/lower flammability or explosive limits: No data found.
Vapor pressure: No data found.
Vapor density: No data found.
Evaporation rate: No data found.
Flammability (solid, gas): No data found.
Partition coefficient: n-octanol/water: No data found.
Solubility: Soluble 28.1 g/100g of water @ 0C.
Viscosity: No data found.
Molecular Weight: 74.55
Chemical Formula: KCl

10. Stability and Reactivity

Stability: Stable under ordinary conditions of use and storage.
Hazardous Decomposition Products: Oxides of the contained metal and halogen, also free, or ionic halogen.
Hazardous Polymerization: Will not occur.
Incompatibilities: Bromine trifluoride; potassium permanganate plus sulfuric acid.
Conditions to Avoid: No information found.

11. Toxicological Information

Oral rat LD50: 2600 mg/kg
Irritation eye rabbit (standard Draize): 500 mg/24 hr. mild.
Carcinogenicity: No component of this product present at levels greater than or equal to 0.1% is identified as possible or confirmed human carcinogen by IARC, ACGIH, OSHA and NTP.
Teratogenic Effects: No data found.
Mutagenic Effects: Investigated as a mutagen.
Developmental Toxicity: No data found.
Reproductive Effects: No data found.

12. Ecological Information

Toxicity to fish:
LC50 - Pimephales promelas (fathead minnow) - 880 mg/l - 96 h
Mortality NOEC - Pimephales promelas (fathead minnow) - 500 mg/l - 7 d
Mortality LOEC - Pimephales promelas (fathead minnow) - 1.000 mg/l - 7 d
Toxicity to daphnia and other aquatic invertebrates: EC50 - Daphnia magna (Water flea) - > 440 mg/l - 48 h
Results of PBT and vPvB assessment: This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

13. Disposal Considerations

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility.

14. Transport Information

DOT USA, TDG Canada & ADR/RID Europe: Not controlled.
IATA/ICAO: Not controlled.
IMDG/IMO: Not controlled.

15. Regulatory Information

USA:
California Proposition 65
: Not listed.
SARA 311/312: See section 2.

Section 16 - Additional Information

DISCLAIMER: The information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed correct as of the date hereof. It is compiled from various sources, and it is not necessarily all inclusive nor fully adequate in every circumstance. In addition, these suggestions should not be confused with nor followed in violation of applicable laws, regulations, rules, or insurance requirements applicable. This SDS MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a professionally trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose. This shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. In no case shall our company be liable to loss or damages by the product user.

Potassium Chloride Suppliers

Please visit Technical Data Sheet of Potassium Chloride USP BP Ph Eur IP Reagent FCC Food Grade Suppliers.

Potassium Chloride CAS Number 7447-40-7 & Potassium Iodide CAS Number 7447-40-7 Supplier Exporter, Manufacturer:

Annie Chemie P Ltd
Mumbai 4000010, INDIA
With Agents and offices in UAE, USA, Europe.

e-mail: info@anniechemie.com

Copyright and Usual Disclaimer is Applicable.
September 29, 2023

Exporters to USA, Canada, UK, Europe, UAE, Nigeria, Algeria, Turkey, Mexico, Brazil, Chile, Argentina, Australia, Dubai etc.

Perfection is made up of small things and that is a big thing.